Product Specification
| Performance properties | Strain range | ±2000μɛ5) | |
| Accuracy (guaranteed)1) | <0.5% FS3) | ||
| Accuracy (typical)1) | <0.23% FS3) | ||
| Precision (guaranteed)2) | <0.25% FS3) | ||
| Precision (typical)2) | <0.15% FS3) | ||
| Temperature compensation | Integrated | ||
| Temperature accuracy1) | <1°C | ||
| Temperature precision2) | ±0.3°C | ||
| Temperature resolution | 0.05°C | ||
| Temperature sensitivity | 28pm/K | ||
| Strain sensitivity | 1,2pm/µɛ | ||
| Operating Temperature range | -20°C to +60°C | ||
| Ingress Protection rating | IP 67 | ||
| Physical properties | Housing material | 316L – 1.4404 | |
| Anchoring distance | 39 ± 2 mm | ||
| Dimensions (without cable)6) | 123 x 35 x 8.5 mm | ||
| Weight (without cable) | 100 g | ||
| Cable type | 3mm Dyneema reinforced cable | ||
| Cable length7) | 1m | ||
| Cable Bend Radius (dynamic) | 40mm | ||
| Cable Bend Radius (static) | 30mm | ||
| Connector type8) | FC/APC | ||
| Mounting method | Screws, glue or spot welding9) | ||
| Packaging | Cardboard box with dimensions: 370 x 290 x 45mm | ||
| Quality Statement | The SWS-02 sensor is compliant with IEC 61757-1-1:2020, 61757-2-1:2021, and 61757:2026. All sensors are 100% tested and calibrated at SYLEX. The sensor is manufactured according to ISO 9001:2008 and ISO 14001:2004. | ||
Notes:
- 1) Accuracy is established for each sensor under laboratory conditions, and it includes hysteresis, non-linearity, and repeatability of the sensor. The guaranteed value is determined based on the largest absolute error found in this sample. The typical value is determined based on the average absolute error found in this sample.
- 2) Precision is established on a batch basis and includes hysteresis, non-linearity, repeatability, and reproducibility of the sensor. The guaranteed value is determined based on the largest absolute error found in this sample. The typical value is determined based on the average absolute error found in this sample.
- 3) FS: full-scale measurement range.
- 4) The temperature range can be extended for operation from -35°C to +70°C.
- 5) The operational strain range of the sensor can be increased by applying different installation methods, i.e. by installation using screws. Considering the installation method, the strain range can be increased to ±5000μɛ.
- 6) See the product drawing for further dimensional details.
- 7) Cable length is extendable upon request.
- 8) Other connector types available upon request.
- 9) For details of what the spot-weldable plate looks like, see Figure 1.